UltraSteamLine - on line and global structural health monitoring of high temperature steam lines
Funder: EPSRCDuration: September 2013 - August 2016
People
Name | Telephone | Office | ||
---|---|---|---|---|
Professor Tat-Hean Gan Professor of Structural Integrity of Metallic Materials and Director of App (Principal investigator)
T: +44 (0)1895 268920
E: tat-hean.gan@brunel.ac.uk |
+44 (0)1895 268920 | tat-hean.gan@brunel.ac.uk | Gardiner 001c |
Outputs
Dhutti, A., Tumin, SA., Mohimi, A., Kostan, M., Gan, TH., Balachandran, W. and et al. (2016) 'Development of low frequency high temperature ultrasonic transducers for in-service monitoring of pipework in power plants'.30th Eurosensors Conference. Budapest, HUNGARY. 4 - 7 September. Elsevier BV. pp. 983 - 986. ISSN: 1877-7058 Open Access Link