HotPhasedArray (HitProbe) - High temperature pipe structural health monitoring system utilising phased array probes on TOFD configuration
Funder: European CommissionDuration: January 2014 - December 2015
People
Name | Telephone | Office | ||
---|---|---|---|---|
Professor Tat-Hean Gan Professor of Structural Integrity of Metallic Materials and Director of App (Principal investigator)
T: +44 (0)1895 268920
E: tat-hean.gan@brunel.ac.uk |
+44 (0)1895 268920 | tat-hean.gan@brunel.ac.uk | Gardiner 001c |
Outputs
Kostan, M., Nageswaran, C., Gan, TH. and Kanfoud, J. (2017) 'Ultrasonic probe using advanced piezoelectric single crystal gallium orthophosphate for NDT at 580°C'. WCCM 2017 - 1st World Congress on Condition Monitoring 2017.
Kostan, M., Mohimi, A., Nageswaran, C., Gan, TH., Wrobel, L. and Selcuk, C. (2016) 'High temperature gallium orthophosphate transducers for NDT and monitoring purposes in nuclear power plants'.55th Annual British Conference of Non-Destructive Testing. Nottingham. 14 - 14 September. 55th Annual Conference of the British Institute of Non-Destructive Testing, NDT 2016. pp. 360 - 369.Open Access Link
Kostan, M., Mohimi, A., Nageswaran, C., Dhutti, A., Gan, T-H., Wrobel, L. and et al. (2016) 'High temperature gallium orthophosphate transducers for NDT'.30th Eurosensors Conference. Budapest, HUNGARY. 1 - 7 September. Elsevier BV. pp. 987 - 990. ISSN: 1877-7058 Open Access Link
Kostan, M., Mohimi, A., Nageswaran, C., Kappatos, V., Cheng, L., Gan, T-H., et al. (2016) 'Assessment of Material Properties of Gallium Orthophosphate Piezoelectric Elements for Development of Phased Array Probes for Continuous Operation at 580 degrees C'.5th International Conference on Materials and Applications for Sensors and Transducers (IC-MAST). Mykonos, GREECE. 1 - 30 September. IOP Publishing. pp. 012008 - 012008. ISSN: 1757-8981 Open Access Link